Catalogue
Find your compound

Create your compound

Step 1 Select the compound application
Шаг 2 Select from the list
Шаг 3 Select from the list
Select from the list

EN 50363-7 type TI 7 VDE 0207 HJ2

EN 50363-7 type TI 7 VDE 0207 HJ2

EN 60332-1- 2 IEC 60332 Part 21, 22, 23, 24 (Categories A F/R, A, B & C) EN 61034-2 IEC 60754-1, 2 Test LOCA

Step 4 The process of overlay filling ...
Tandem
Two-stage

BS 6724 DIN VDE 0472 part 814

EN 60332-1- 2 IEC 60332 Part 21, 22, 23, 24 (Categories A F/R, A, B & C) EN 61034-2 IEC 60754-1, 2 Test LOCA

Step 4 Select from the list

EN 50363-8 type TM 7 VDE 0207 HM2-HM4 BS 7655 LTS 1-2- 3-4 IEC 60502-1 ST-8

EN 50363-8 type TM 7 VDE 0207 HM2-HM4 BS 7655 LTS 1-2- 3-4 IEC 60502-1 ST-8

EN 50363-8 type TM 7 VDE 0207 HM2-HM4 BS 7655 LTS 1-2- 3-4 IEC 60502-1 ST-8

Step 5 Are there any special requirements for cold resistance, oil resistance and diesel fuel?
Step 6 Select from the list ...
Low temperature properties (-50, -60°С)

EN 50363-8 type TM 7 BS 7655 LTS 1-2- 3-4 VDE 0207 HM2-HM4 IEC 60502-1 ST-8

EN 50363-8 type TM 7 VDE 0207 HM2-HM- 4 BS 7655 LTS 1-2- 3-4 EC 60502-1 ST-8

EN 45545-2 EN 50306 EN 50264 IEC 60092-359 type SHF1

EN 45545-2 EN 50306 EN 50264 IEC 60092-359 type SHF-1

EN 45545-2 EN 50306 EN 50264 IEC 60092-359 type SHF-1

Resistance to hydrocarbons (Oil resistance (IRM 902) and diesel resistance)

EN 50363-8 type TM 7 VDE 0207 HM2-HM- 4 BS 7655 LTS 1-2- 3-4 EC 60502-1 ST-8

EN 45545-2 EN 50306 EN 50264 IEC 60092-359 type SHF1

EN 45545-2 EN 50306 EN 50264 IEC 60092-359 type SHF-1

EN 45545-2 EN 50306 EN 50264 IEC 60092-359 type SHF-1

Step 6 Cable with insulation from
XLPE

EN 50363-8 type TM 7 VDE 0207 HM2-HM4 IEC 60502-1 ST-8 BS 7655 LTS 1-2- 3-4

BS 7655 LTS 1-2- 3-4 EN 50363-8 type TM 7 VDE 0207 HM2-HM4 IEC 60502-1 ST-8

EN 60332-1- 2 IEC 60332 Part 21, 22, 23, 24 (Categories A F/R, A, B & C) EN 61034-2 IEC 60754-1, 2 Test LOCA

HFFR

EN 50363-8 type TM 7 BS 7655 LTS 1-2- 3-4 VDE 0207 HM2-HM4 IEC 60502-1 ST-8

EN 50363-8 type TM 7 VDE 0207 HM2-HM4 BS 7655 LTS 1-2- 3-4 IEC 60502-1 ST-8

Select from the list...
Select from the list

EN 60332-1- 2 IEC 60332 Part 21, 22, 23, 24 (Categories A F/R, A, B & C) EN 61034-2 (50%) IEC 60754-1 EN50363-3/4/types TI2/TM2 BS7655-3/4 types TI2/TM2

EN50363-3/4/types TI2/TM2 BS7655-3/4 types TI2/TM2 GOST 12.1.044 (low toxic) EN 60332-1- 2 IEC 60332 Part 21, 22, 23, 24 (Categories A F/R, A, B & C) EN 61034-2 (50%) IEC 60754-1

Select from the list...
Select from the list...

PVC type TI 1 according to EN 50363-3 EN 50525 EN 60332-1- 2 BS7655-3

Select from the list...
Oil resistance 120 °С, cold resistance -60 °С

EN50363-3- 1 type TI4 BS7655-3 type TI4

Cold Resistance -40 °С

EN50363-3- 1 type TI5 BS7655- type TI5

No requirements

EN 60332-1- 2 IEC 60332 Part 21, 22, 23, 24 (Categories A F/R, A, B & C) EN 61034-2 (50%) IEC 60754-1 EN50363-3/4/types TI2/TM2 BS7655-3/4 types TI2/TM2

EN50363-3/4/types TI2/TM2 BS7655-3/4 types TI2/TM2 GOST 12.1.044 (low toxic) EN 60332-1- 2 IEC 60332 Part 21, 22, 23, 24 (Categories A F/R, A, B & C) EN 61034-2 (50%) IEC 60754-1

Select from the list...
Operating temperature range
-40 … 90°С

ISO 6722 Class А EN 50363-4 TI3 BS7655-4 type TI3

40 … 105°С

ISO 6722 Class B

ISO 6722 Class B

ISO 6722 Class B

ISO 6722 Class B

-40 … 125°С

ISO 6722 Class C

Select from the list...

PVC type TM 1 according to EN 50363-4- 1 EN 50525 EN 60332-1- 2 BS7655-4

Select from the list...
Oil resistance 100°С, cold resistance -50°С ... -55°С

PVC type TM4-TM5 EN50363-4 BS7655-4 EN 60332-1- 2 IEC 60332 Part 21, 22, 23,24 (Categories A F/R, A, B & C)

PVC type TM4-TM5 EN50363-4 BS7655-4 EN 60332-1- 2 IEC 60332 Part 21, 22, 23,24 (Categories A F/R, A, B & C)

EN50363- 4-1 type TM5 BS7655-type TM5

Oil resistance 120°С, cold resistance -60°С

EN50363- 4-1 type TM5 BS7655 type TM5

Cold resistance -40°С ... -30°С

PVC type TM4 EN50363-4 BS7655-4 EN 60332-1- 2 IEC 60332 Part 21, 22, 23,24 (Categories A F/R, A, B & C)

PVC type TM4 EN50363-4 BS7655-4 EN 60332-1- 2 IEC 60332 Part 21, 22, 23,24 (Categories A F/R, A, B & C)

EN50363- 4-1 type TM4 BS7655-type TM4

Cold resistance -50 °С and below

PVC type TM4 EN50363-4 BS7655-4 EN 60332-1- 2 IEC 60332 Part 21, 22, 23,24 (Categories A F/R, A, B & C)

PVC type TM4 EN50363-4 BS7655-4 EN 60332-1- 2 IEC 60332 Part 21, 22, 23,24 (Categories A F/R, A, B & C)

PVC type TM4 EN50363-4 BS7655-4 EN 60332-1- 2 IEC 60332 Part 21, 22, 23,24 (Categories A F/R, A, B & C)

No requirements

EN 60332-1- 2 IEC 60332 Part 21, 22, 23, 24 (Categories A F/R, A, B & C) EN 61034-2 (50%) IEC 60754-1 EN50363-3/4/types TI2/TM2 BS7655-3/4 types TI2/TM2

EN50363-3/4/types TI2/TM2 BS7655-3/4 types TI2/TM2 GOST 12.1.044 (low toxic) EN 60332-1- 2 IEC 60332 Part 21, 22, 23, 24 (Categories A F/R, A, B & C) EN 61034-2 (50%) IEC 60754-1

Select from the list...

Type ST 2 IEC 60502-1 EN 50363-4 TM3 BS7655-4 type TM3

Last step:

click the create button

if this material(s) does not fully meet your requirements, click: