Compounds for Flame Retardant & Fire Resistant Cables
Grade |
Properties and application areas |
Standards |
|
INSULATION |
|
Promvulk® 13300
|
High extrusion speed. Specially designed for conductors with cross-sections of 0.5-2.5 mm2.
General application |
EN 50363-7 type TI 7
VDE 0207 HJ2 |
|
SHEATING for LV cables |
|
Promvulk® 23400
|
Very flame retardant. High values of temperature index and limiting oxygen index.
For power cables, which contain XLPE-insulation.
Underground, airport, building, public spaces. |
EN 50363-8 type TM 7
VDE 0207 type HM2-HM4
BS 7655 LTS 1-2-3-4
IEC 60502-1 ST-8 |
Promvulk® 23622
|
Flame retardant.
High extrusion speed
For power cables, which contain XLPE-insulation.
Underground, airport, building, public spaces.
Fiber optic cables. |
EN 50363-8 type TM 7
VDE 0207 HM2
BS 7655 LTS 1, LTS 3
IEC 60502-1 ST-8
IEC 60092-359 SHF 1
|
Promvulk® 23300
|
High extrusion speed compound for LV cables, which do not contain XLPE-insulation. Can be used as insulation compound
Cost effective.
For power, data communication, block signaling and control cables in general installations applications. Used in cables with conductor`s cross-section less than 35 mm2. |
EN 50363-8 type TM 7
BS 7655 LTS 1, LTS 3
VDE 0207 HM2
IEC 60502-1 ST-8
IEC 60092-359 SHF 1 |
Promvulk® 24000
|
Very flame retardant. Excellent char formation.
For power cables with XLPE-insulation.
Underground, airport, building, public spaces.
|
BS 7655 LTS 1, LTS 3
EN 50363-8 type TM 7
VDE 0207 HM2
IEC 60502-1 ST-8
EN 13501-6 B2ca (s1, d0) |
Promvulk® 23200
|
Flame retardant.
Low temperature flexibility. Service temperatures - 30… + 90.
Рower cables with XLPE-insulation for Arctic regions. |
EN 50363-8 type TM 7
BS 7655 LTS 1-2-3-4
VDE 0207 HM2, HM4
IEC 60502-1 ST-8
IEC 60092-359 SHF 1 |
Promvulk® 23700
|
Flame retardant.
Low temperature flexibility. Service temperatures - 45… + 80.
Power cables with XLPE-insulation for Arctic regions. |
EN 50363-8 type TM 7
BS 7655 LTS 1, LTS 3
VDE 0207 HM2
IEC 60502-1 ST-8
IEC 60092-359 SHF 1 |
|
|
|
Promvulk® 23400 |
Promvulk® 23622 |
Promvulk® 23300 |
Promvulk® 13300 |
|
|
|
sheathing |
sheathing |
sheathing, insulation |
insulation |
Density |
IEC 60811-1-3 |
g/cm3
(±0,02) |
1.55 |
1.50 |
1.48 |
1.48 |
Hardness |
ISO 868 |
Shore D (±3) |
52 |
53 |
51 |
51 |
Tensile strength |
IEC 60811-501 |
MPa |
≥11 |
≥11 |
≥10 |
≥11 |
Elongation
at break |
IEC 60811-501 |
% |
≥150 |
≥200 |
≥160 |
≥200 |
Limiting Oxygen Index |
ISO 4589 |
% O2 |
42 |
38 |
32 |
28 |
M.F.I.
(21.6 kg, 190 °C) |
ISO 1133 |
g/10 min |
6.5 |
8 |
11.5 |
14 |
Volume resistivity at 20 °C |
ASTM D257 |
Ω·сm |
1•1014 |
3•1014 |
6•1014 |
5•1014 |
|
|
|
Promvulk® 24000 |
Promvulk® 23200 |
Promvulk® 23700 |
|
|
|
sheathing |
sheathing |
sheathing |
Density |
IEC 60811-1-3 |
g/cm3
(±0,02) |
1.55 |
1.52 |
1.54 |
Hardness |
ISO 868 |
Shore D (±3) |
54 |
54 |
52 |
Tensile strength |
IEC 60811-501 |
MPa |
≥11 |
13.5 |
14 |
Elongation
at break |
IEC 60811-501 |
% |
≥160 |
190 |
160 |
Limiting Oxygen Index |
ISO 4589 |
% O2 |
37 |
37 |
33 |
M.F.I.
(21.6 kg, 190 °C) |
ISO 1133 |
g/10 min |
2 |
4 |
2.5 |
Cold Elongation
(-30 ± 2°C) |
EN 60811-505
|
% |
- |
40 |
60 |
Oil and diesel fuel resistant compounds
Grade |
Properties and application areas |
Standards |
Lowstek® 2020,
Lowstek® 2030,
|
Low temperature flexibility (-60°C),
IRM 902 oil resistant at 120ºC,
Diesel fuel resistant at 100ºC
For power cables in Arctic region
Rolling stock, shipboard, offshore rig. |
EN 45545-2
EN 50306
EN 50264
IEC 60092-359 type SHF-1 |
Lowstek® 2040
|
Low temperature flexibility (-60°C),
IRM 902 oil resistant at 120ºC,
Diesel fuel resistant at 100ºC
Improved processing.
For power cables in Arctic region
Rolling stock, shipboard, offshore rig. |
EN 45545-2
EN 50306
EN 50264
IEC 60092-359 type SHF-1 |
Lowstek® 201
|
Low temperature flexibility (-50ºC).
IRM 902 oil resistant at 70ºС.
For power and control cables
Shipboard, offshore rig. |
EN 50363-8 type TM 7
VDE 0207 HM2-HM-4
BS 7655 LTS 1-2-3-4
IEC 60502-1 ST-8 |
|
|
|
Lowstek® 2020 |
Lowstek® 2030 |
Lowstek® 2040 |
Lowstek® 201 |
|
|
|
sheathing |
sheathing |
sheathing |
sheathing |
Density |
IEC 60811-1-3 |
g/cm3
(±0,02) |
1.59 |
1.59 |
1.57 |
1.49 |
Hardness |
ISO 868 |
Shore D (±3) |
38 |
41 |
40 |
50 |
Tensile strength |
IEC 60811-501 |
MPa |
≥11 |
≥12 |
≥10 |
≥12 |
Elongation
at break |
IEC 60811-501 |
% |
≥220 |
≥200 |
≥200 |
≥150 |
Limiting Oxygen Index |
ISO 4589 |
% O2 |
36 |
36 |
34 |
36 |
M.F.I.
(21.6 kg, 190 °C) |
ISO 1133 |
g/10 min |
7.5 |
11 |
6 |
5.5* |
IRM-902 Oil resistance |
IEC 60811-2-1
|
|
24h @ 120 °C
|
24h @ 120 °C |
24h @ 120 °C |
48h @ 25 °C
4h @ 70 °C |
Diesel fuel resistance |
IEC 60811-2-1
|
|
24h @ 100 °C |
24h @ 100 °C |
24h @ 100 °C |
24h @ 25 °C |
Cold Elongation
(-60 ± 2 °C) |
EN 60811-505
|
% |
> 30 |
> 30 |
> 30 |
> 30
(at -40°C) |
*M.F.I. (21.6 kg, 150 °C)
Environmental stress crack resistant compounds
Grade |
Properties and application areas |
Standards |
Alovin® 110 |
Good tensile at high temperature and crack resistance. Very high tear resistance.
Power cables for hot and tropical climates.
Sheathing for 110 kV high voltage power cables |
EN 50363-8 type TM 7
VDE 0207 HM2-HM4
BS 7655 LTS 1-2-3-4
IEC 60502-1 ST-8 |
Promvulk® 23600 UV
|
UV resistant sheathing compound with good crack resistance for hot and desert climates. High level of flame retardancy.
For installation wires and following types of flame retardant cables: power, control, conducting, block signaling, communication. |
EN 50363-8 type TM 7 VDE 0207 type HM2-HM4
BS 7655 type LTS 1-2-3-4,
IEC 60502-1 type ST-8 |
|
|
|
Alovin® 110 |
Promvulk® 23600 UV |
|
|
|
sheathing |
sheathing |
Density |
IEC 60811-1-3 |
g/cm3
(±0,02) |
1.50 |
1.49 |
Hardness |
ISO 868 |
Shore D (±3) |
59 |
55 |
Tensile strength |
IEC 60811-501 |
MPa |
≥15 |
≥13 |
Elongation
at break |
IEC 60811-501 |
% |
≥200 |
≥160 |
Tear resistance |
BS 6469 |
N/mm2 |
16 |
≥8 |
Limiting Oxygen Index |
ISO 4589 |
% O2 |
35 |
35 |
M.F.I.
(21.6 kg, 190 °C) |
ISO 1133 |
g/10 min |
4 |
6 |
IRM-902 Oil resistance |
IEC 60811-2-1
|
|
4h @ 70 °C |
4h @ 70 °C |
|
|
|
|
|
Sheathing compounds are available in natural and black colors, UV-stabilized. They can be manufactured as rodent, fungal and termite resistant.
Bedding compounds
Grade |
Properties and application areas |
Standards |
Promvulk® 33100
|
For tandem extrusion only. EVA based.
Very flame retardant. High value of limiting oxygen index.
For power & control cables with special fire performance (CPR) |
|
Promvulk® 33100-3
|
For tandem extrusion only. EVA-EPDM based.
Flame retardant. For power & control cables |
|
Promvulk® 33300
|
Flexible, for 2-step process. EVA based. Flame retardant.
Bedding for armored cables.
|
BS 6724
DIN VDE 0472 part 814 |
Promvulk® 33500 |
Flexible, for 2-step process. EVA based. Flame retardant.
Bedding for armored cables. Improved hardness |
|
Promvulk® 33600
|
Flexible, for 2-step process. EVA based. Flame retardant.
Environmental stress crack resistant bedding.
|
BS 7655 LTS 2
|
|
|
|
Promvulk® 33100 |
Promvulk® 33100-3 |
Promvulk® 33300 |
Promvulk® 33500 |
Promvulk® 33600 |
|
|
|
bedding |
bedding |
bedding |
bedding |
bedding |
|
|
|
tandem |
tandem |
two step |
two step |
two step |
Density |
IEC 60811-1-3 |
g/cm3
(±0,02) |
1.90 |
1.94 |
1.70 |
1.67 |
1.5 |
Hardness |
ISO 868 |
Shore D (±3) |
92 (Shore A) |
92 (Shore A) |
48 |
61 |
52 |
Tensile strength |
IEC 60811-501 |
MPa |
- |
- |
≥7 |
≥12 |
≥12 |
Elongation
at break |
IEC 60811-501 |
% |
- |
- |
≥100 |
≥80 |
≥170 |
Limiting Oxygen Index |
ISO 4589 |
% O2 |
70 |
38 |
40 |
43 |
35 |
M.F.I.
(21.6 kg, 190 °C) |
ISO 1133 |
g/10 min |
5* |
11* |
2 |
3 |
12.5** |
*M.F.I. (21.6 kg, 100 °C)
**M.F.I. (21.6 kg, 150 °C)
Oil and diesel fuel resistant PVC compounds
Grade |
Properties and application areas |
Standards |
|
SHEATING |
|
NGP 50-32М,
NGP 55-30М
|
IRM 902 oil resistant (100°С)
UV-Resistant
Flexible at low temperature (-50, -55ºC, depending on grade). |
PVC type TM4-TM5
EN50363-4
BS7655-4
EN 60332-1-2
IEC 60332 Part 21, 22, 23,24 (Categories A F/R, A, B & C) |
Lowsgran® 23514 |
IRM 902 oil resistant (100ºС)
Low temperature flexibility (-50ºC)
UV-resistant
Low smoke emission |
EN50363- 4-1 type TM5
BS7655-type TM5 |
Lowsgran® 200 |
Very flame retardant with low smoke emission
IRM 902 oil resistance (120ºС)
Low temperature flexibility (-60ºC) |
EN50363- 4-1 type TM5
BS7655 type TM5 |
|
INSULATION |
|
Lowsgran® 102 |
Very flame retardant with low smoke emission
IRM 902 oil resistance (120ºС)
Low temperature flexibility (-60ºC) |
EN50363-3-1 type TI4
BS7655-3 type TI4
|
Sheathing compounds are available in natural and black colors |
|
|
|
|
|
|
|
|
NGP 50-32М |
NGP 55-30М |
Lowsgran® 23514 |
Lowsgran® 200 |
Lowsgran® 102 |
|
|
|
sheathing |
sheathing |
sheathing |
sheathing |
insulation |
Density |
IEC 60811-1-3 |
g/cm3
(±0,02) |
1.39 |
1.36 |
1.58 |
1.52 |
1.43 |
Hardness |
ISO 868 |
Shore D (±3) |
76 |
70 |
87 |
90 |
84 |
Tensile strength |
IEC 60811-501 |
MPa |
15 |
14 |
13 |
15 |
16 |
Elongation
at break |
IEC 60811-501 |
% |
330 |
370 |
300 |
300 |
300 |
Limiting Oxygen Index |
ISO 4589 |
% O2 |
32 |
30 |
31 |
50 |
40 |
Smoke density |
ASTM E-662 |
Ds max |
|
|
200 |
250 |
300 |
Cold bend temperature |
IEC 60811-1-4
IEC 60811-504
|
°С |
-50 |
-55 |
|
|
|
Volume resistivity at 20 °C |
ASTM D257
|
Ω·сm |
2•1012 |
5•1011 |
8•1013 |
4•1013 |
6•1013 |
Cold flex PVC compounds
Grade |
Properties and application areas |
Standards |
|
SHEATING |
|
NGP 30-32,
NGP 40-32,
NGP 50-32,
NGP 50-35,
NGP 55-32 |
General use.
For medium flexibility cables.
UV-Resistant
Flexible at low temperature (-30, -40, -50, -55ºC, depending on grade). |
PVC type TM4
EN50363-4
BS7655-4
EN 60332-1-2
IEC 60332 Part 21, 22, 23,24 (Categories A F/R, A, B & C) |
Lowsgran® 23513 |
General purpose compound.
Low temperature flexibility (-40ºC)
UV-resistant
Low smoke emission |
EN50363- 4-1 type TM4
BS7655-type TM4
|
Sheathing compounds are available in natural and black colors |
|
|
INSULATION |
|
Lowsgran® 13414 |
General purpose compound
Low temperature flexibility (-40ºC)
Low smoke emission |
EN50363-3-1 type TI5
BS7655- type TI5 |
|
|
|
|
|
|
|
NGP 30-32 |
NGP 40-32 |
NGP 50-32 |
NGP 50-35 |
NGP 55-32 |
Lowsgran® 23513 |
Lowsgran® 13414 |
|
|
|
sheathing |
sheathing |
sheathing |
sheathing |
sheathing |
sheathing |
insulation |
Density |
IEC 60811-1-3 |
g/cm3
(±0,02) |
1.5 |
1.5 |
1.44 |
1.44 |
1.43 |
1.55 |
1.55 |
Hardness |
ISO 868 |
Shore D (±3) |
88 |
83 |
84 |
85 |
84 |
88 |
89 |
Tensile strength |
IEC 60811-501 |
MPa |
16 |
14 |
15 |
15 |
17 |
14 |
10 |
Elongation
at break |
IEC 60811-501 |
% |
300 |
300 |
320 |
320 |
300 |
270 |
150 |
Limiting Oxygen Index |
ISO 4589 |
% O2 |
32 |
32 |
32 |
32 |
32 |
30 |
29 |
Smoke density |
ASTM E-662 |
Ds max |
|
|
|
|
|
200 |
200 |
Cold bend temperature |
IEC 60811-1-4
IEC 60811-504
|
°С |
-30 |
-40 |
-50 |
-50 |
-55 |
|
|
Volume resistivity at 20 °C |
ASTM D257
|
Ω·сm |
1•1013 |
1•1013 |
1,5•1012 |
1,5•1012 |
1,5•1012 |
9•1013 |
1•1014 |
Low smoke flame retardant PVC
Grade |
Properties and application areas |
Standards |
|
SPECIAL PURPOSE SETS |
|
Lowsgran® 1110
Lowsgran® 2110
Lowsgran® 3110 |
Very flame retardant, low smoke & corrosive fume emission.
For cables used in underground, airports, petrochemical plants, hotels, hospitals and high-rise buildings.
General purpose for fixed installation cables
|
EN 60332-1-2
IEC 60332 Part 21, 22, 23, 24 (Categories A F/R, A, B & C)
EN 61034-2 (50%)
IEC 60754-1
EN50363-3/4/types TI2/TM2
BS7655-3/4 types TI2/TM2 |
Lowsgran® 1010
Lowsgran® 2010
Lowsgran® 3010 |
Very flame retardant. Specially developed to meet the requirements of smoke toxicity by GOST 12.1.044 (low toxic).
For Flame Retardant LTx cables |
EN50363-3/4/types TI2/TM2
BS7655-3/4 types TI2/TM2
GOST 12.1.044 (low toxic)
EN 60332-1-2
IEC 60332 Part 21, 22, 23, 24 (Categories A F/R, A, B & C)
EN 61034-2 (50%)
IEC 60754-1 |
Sheathing compounds are available in natural and black colors |
|
|
BEDDING |
|
Lowsgran® 33613 |
General purpose compound. Good flexibility and low temperature performance |
|
|
|
|
|
|
|
|
Lowsgran® 1110 |
Lowsgran® 1010 |
Lowsgran® 2110 |
Lowsgran® 2010 |
Lowsgran® 200 |
|
|
|
insulation |
insulation |
sheathing |
sheathing |
sheathing |
Density |
IEC 60811-1-3 |
g/cm3
(±0,02) |
1.60 |
1.62 |
1.66 |
1.65 |
1.52 |
Hardness |
ISO 868 |
Shore A (±3) |
90 |
91 |
92 |
91 |
90 |
Tensile strength |
IEC 60811-501 |
MPa |
13.0 |
12.5 |
11.5 |
11.5 |
15 |
Elongation
at break |
IEC 60811-501 |
% |
270 |
260 |
250 |
240 |
300 |
Limiting Oxygen Index |
ISO 4589 |
% O2 |
32 |
32 |
35 |
34 |
50 |
Smoke density |
ASTM E-662 |
Ds max |
150 |
130 |
140 |
120 |
250 |
Volume resistivity at 20 °C |
ASTM D257
|
Ω·сm |
8•1013 |
8•1013 |
8•1013 |
8•1013 |
4•1013 |
|
|
|
Lowsgran® 3110 |
Lowsgran® 3010 |
Lowsgran® 33613 |
|
|
|
|
bedding |
bedding |
bedding |
|
Density |
IEC 60811-1-3 |
g/cm3
(±0,02) |
1.87 |
1.89 |
1.66 |
|
Hardness |
ISO 868 |
Shore A (±3) |
91 |
91 |
90 |
|
Tensile strength |
IEC 60811-501 |
MPa |
4.6 |
5.0 |
11.0 |
|
Elongation
at break |
IEC 60811-501 |
% |
170 |
175 |
220 |
|
Limiting Oxygen Index |
ISO 4589 |
% O2 |
31 |
32 |
28 |
|
Smoke density |
ASTM E-662 |
Ds max |
120 |
80 |
80 |
|
General application PVC compounds
Grade |
Properties and application areas |
Standards |
|
SHEATING |
|
OM 20-12 |
General use. Not flame retardant.
For installation cables. |
PVC type TM 1
according to
EN 50363-4-1
EN 50525
EN 60332-1-2
BS7655-4 |
Sheathing compounds are available in natural and black colors |
|
|
INSULATION |
|
IМ 30-13 |
General use. Not flame retardant.
For installation cables.
|
PVC type TI 1
according to
EN 50363-3
EN 50525
EN 60332-1-2
BS7655-3 |
|
|
|
|
|
|
|
OM 20-12 |
IМ 30-13 |
|
|
|
|
sheathing |
insulation |
|
Density |
IEC 60811-1-3 |
g/cm3
(±0,02) |
1.55 |
1.49 |
|
Hardness |
ISO 868 |
Shore A (±3) |
89 |
90 |
|
Tensile strength |
IEC 60811-501 |
MPa |
15 |
18 |
|
Elongation
at break |
IEC 60811-501 |
% |
280 |
300 |
|
Limiting Oxygen Index |
ISO 4589 |
% O2 |
- |
- |
|
Cold bend temperature |
IEC 60811-1-4
IEC 60811-504 |
°С |
-20 |
-30 |
|
Volume resistivity at 20 °C |
ASTM D257
|
Ω·сm |
1•1013 |
1•1014 |
|
PVC compounds for automotive industry
(RoHS & REACH compliant)
Grade |
Properties and application areas |
Standards |
|
INSULATION |
|
IT-90 |
Operating temperature: -40ºC to 90ºC.
|
ISO 6722 Class А
EN 50363-4 TI3
BS7655-4 type TI3 |
IT-105 P-AM PBF |
Operating temperature: -40ºC to 105ºC.
Conductor cross-sections 0.5-4.0 mm2
High extrusion speed material:
conductor cross sections 0.5–1.0 mm2 – up to 1000 m/min,
cross sections 1.5–4.0 mm2- up to 500 m/min |
ISO 6722 Class B |
IT-105 P-AV PBF
|
Operating temperature: -40ºC to 105ºC.
Flexible conductors with cross sections 6.0 mm2-50.0 mm2
For standard wall insulation thickness automotive cables.
Suitable for use in marine applications and battery cables. |
ISO 6722 Class B |
IT-105 P-A-1 PBF
|
Operating temperature: -40ºC to 105ºC.
Conductor cross-sections 0.35-0.5 mm2
High extrusion speed material:
insulation laying speed up to 1100 m/min.
For thin and ultrathin-wall insulation automotive cables.
Reduced insulation thickness and higher current carrying capacity both help to reduce weight and volume in wire harnesses.
Suitable for use marine applications. |
ISO 6722 Class B |
IT-105 P-AM-C PBF
|
Operating temperature: -40ºC to 105ºC .
Hard grade insulation. Excellent abrasion resistance.
Petrol and chemical resistant.
Excellent color stability after thermal ageing. |
ISO 6722 Class B |
IT-125
|
Operating temperature: -40ºC to 125ºC.
Conductor cross sections 0.75 – 4.0 mm2.
Suitable for heating wires, flexible connections of electrical equipment and appliances, for accumulator and starter connections with rated voltage up to 48 V. |
ISO 6722 Class С |
|
SHEATING |
|
OT-90
|
Operating temperature: -40ºC to 90ºC.
For sheathing power & control cables with extruded insulation for rated voltages of 1 kV and 3 kV.
|
Type ST 2
IEC 60502-1
EN 50363-4 TM3
BS7655-4 type TM3 |
|
|
|
IT-90 |
IT-105 P-AM PBF |
IT-105 P-AV PBF |
IT-105 P-A-1 PBF |
IT-105 P-AM-C PBF |
IT-125 |
OT-90 |
|
|
|
insulation |
insulation |
insulation |
insulation |
insulation |
insulation |
sheathing |
Density |
IEC 60811-1-3 |
g/cm3
(±0,02) |
1.35 |
1.36 |
1.31 |
1.35 |
1.36 |
1.36 |
1.44 |
Hardness |
ISO 868 |
Shore A (±3) |
83 |
96 |
83 |
97 |
95 |
96 |
85 |
Tensile strength |
IEC 60811-501 |
MPa |
19 |
25 |
20 |
26 |
24 |
24 |
15 |
Elongation
at break |
IEC 60811-501 |
% |
300 |
290 |
320 |
290 |
290 |
290 |
300 |
Thermal stability
at 200 °C |
IEC 60811-3-2 |
min |
180 |
200 |
220 |
230 |
290 |
300 |
160 |
Volume resistivity at 20 °C |
ASTM D257
|
Ω·сm |
5•1013 |
8•1013 |
6•1013 |
8•1013 |
8•1013 |
2•1014 |
8•1013 |